Electrically isolated, high-impedance pH measurement and precision peristaltic dosing with proportional control logic.
Designed for double-junction silver nitrate probes. Compatible with BlueLab, Dosatron, and any professional-grade pH electrode.
Encrypted SMS and telephone voice alerts when parameters exceed your thresholds.
pH electrodes are high-impedance voltage sources. The glass membrane that makes pH measurement possible also means the signal is extremely fragile — electrode impedances typically sit in the hundreds of megaohms to gigaohm range. Most consumer pH meters cut corners here. We don't.
Our front end uses full electrical isolation with an input impedance exceeding 10 GΩ — high enough to properly interface with laboratory-grade electrodes without signal degradation. This allows us to support double-junction, silver nitrate reference probes — the type used in professional and scientific applications.
The result is accurate, stable pH readings that don't drift or suffer from noise — even in electrically noisy environments with pumps, solenoids, and other equipment running on the same circuits.
The secondary junction acts as a barrier, dramatically extending probe life in nutrient-rich solutions
Silver/silver chloride references maintain consistent potential over time, unlike cheap gel-filled electrodes
No interference from pumps, solenoids, or other equipment sharing your electrical system
Calculate ΔpH between current reading and setpoint
Larger deviation = larger dose. Small deviation = micro-dose. Approaching target = hold.
System tracks cumulative doses and adjusts for decreasing reservoir volume
Precision pump allows exact volume delivery — no guesswork
Most pH dosers operate on fixed-dose logic: if pH deviates from target, dump X millilitres. Wait. Repeat. This works, but it's crude — you overshoot, undershoot, oscillate around your setpoint.
Our system uses subtractive proportional logic. The dose volume scales with the deviation from target. Far from setpoint? Larger dose. Close to setpoint? Micro-dose. At setpoint? Hold.
The algorithm also estimates remaining reservoir volume based on cumulative dosing history, adjusting its calculations as your water level drops. Pair with our optional water level sensor for exact volume tracking.
Peristaltic pumps deliver exact volumes by displacing fluid through flexible tubing. No contamination between pump mechanism and fluid. No priming. Consistent delivery regardless of viscosity.
The display model includes a capacitive touchscreen with a custom interface. Responsive, smooth, with real-time graphs and direct control — works like a smartphone.
Or skip the screen entirely and use our web interface or mobile app. The headless unit is functionally identical — the display is purely a convenience for on-site interaction.
All configurations available with 2 week lead time. Shipping worldwide.